Products |
 |
|
|
|
|
|
|
|
 |
|
 |
|
High Voltage Ignition Cable for Automobiles |
|
 |
|
|
|
|
|
High
Voltage Ignition Cable for Automobiles
Type and Designation
Type |
Designation |
QGV |
Copper conducted PVC insulated
high voltage ignition cable for automobiles |
QGV-105 |
Copper conducted PVC insulated
105℃ high voltage ignition cable for automobiles |
QGF |
Copper conducted PVC-butyronitrile
compound insulated high voltage ignition
cable for automobiles |
QGXF |
Copper conducted NR-SBR
insulated CR sheathed high voltage ignition
cable for automobiles |
QGXV |
Copper conducted NR-SBR
insulated PVC sheathed high -tension ignition
cable for automobiles |
Description of the Purpose
Having the properties
of withstanding high voltage of more than 15 kV,
corona-proof, and excellent resistance to high temperature,
oil and abrasion, the cable is widely used in the
engine igniting system of automobiles.
Standard
GB /T 14820.2-935 |
Construction
and Specification(mm)
Cable Code |
Nominal cross sectional
area of conductor(mm2) |
Minimumstrand of conductor |
Insulation thickness |
Sheath thickness |
Outerdiameter |
QGV、QGFQGV-105 |
QGXFQGXV |
QGXF、QGXV |
1 |
1 |
19 |
1.70 |
0.90 |
0.8 |
5±0.3 |
2 |
1 |
19 |
2.70 |
1.70 |
0.9 |
7±0.3 |
3 |
1 |
19 |
3.20 |
2.20 |
0.9 |
8±0.3 |
|
Main technical performance
Test Item |
Requirement |
Result |
Test Standard |
30min AC voltage test,
continuous voltage-raising test, corona
resistance test |
No break down |
No break down |
GB 3048 GB 14820 |
Heat shrink test |
No cracks |
No cracks |
GB 2951 |
Fire test |
Pass |
Pass |
GB 12666 |
Low temperature flexible
test |
No cracks |
No cracks |
GB 14820 |
Oil resistance test |
Pass |
Pass |
GB 14820 |
Fast aging test |
Pass |
Pass |
GB 14820 |
|
|
|
|
|
|
|
|
|